TROUBLED WATERS
TECHNICAL COMPARISON KOLD STER-IL ® R/O
(Hyper/Nano Filtration) SYSTEMS
*Note: Required 55-60 psig. Minimum
pressure on membrane
Explanation of Water Quality ANSI/NSF Testing Protocols
ANSI/NSF Test Protocol 42 (Chlorine, Odor & Taste) Standard
#42.
A filter cartridge, or other form of filter media, must remove +95% of 2.0
mg/L solution of free chlorine (at both acidic and basic pH Range) for a
minimum of 1500 gallons. The flow rate for a 10 inch canister is 0.60 gpm.
The filter cartridge must also remove sulfides, additional smells and
metallic taste. Kold Ster-Il ® offers a carbon cartridge capable of 3,000
gallons minimum chlorine (2.0 mg/L concentration neutralization under NSF
Standard 42.
ANSI/NSF Test Protocol 53 Volatile Organic Chemicals/THM's
(Chloroform surrogate test) Standard 53. A filter cartridge, or other form
of filter media, must remove 74% or more to produce a filtrate containing
not more than 0,100 mg/l or 100 µg/l of chloroform detected Gas
Chromatograph with a Electron Capture Detector. Our Kold Ster-il® system
provides 12 molecular absorption discs 74% reduction of 347 µg/L Chloroform
to 90 µg/L then our 0.50 µm carbon filter provides an 82+% reduction of any
residual Chloroform (approved under NSF Standard 53b).
ANSI/NSF Test Protocol 53b Heavy Metals (Lead, Mercury,
Cadmium) Standard #53b. A filter cartridge, or other form of filter media,
must remove lead, mercury and cadmium from potable water under acidic and
basic pH Ranges. Our Kold Ster-il® sorbed 62.45% lead, 63.27% cadmium and
63.47% mercury at 5.90 pH and 7.75 ph flowing 3.78gpm (620 % faster than the
Standard 0.60 gpm required flow rate). Next our 0.50µm carbon filter is
filled with a ceramic molecular sieve that sorbs 96% of lead, 91% of cadmium
and 93% of mercury under ANSI/NSF Standard53b. Method of Analysis: Atomic
Absorption w/Graphite furnace under EPA Methods.
ANSI/NSF Test Protocol 63 Health & Safety related to
extractables. Standard #63
Each Type of Plastic Hardware, end caps, glues and filter media must be
exposed separately to ultrapure water i.e. ASTM Type I 18.0 megohm/cm
(0.56µS/cm) for a minimum of 1 hour in a sealed glass or teflon container.
Samples are drawn through from the sealed container into the purge & trap of
Fas Chromatagraph with an Electron Capture Detector for Volatile Organic
Chemical Analysis. Certain other tests may be required, dependent upon
materials of construction, types of glues and sealants, and filter media
selected. These tests can be for radioactivity (carbons) heavy metals
(zeolites and other minerals) and pesticides.
US-EPA "Guide Standard and Protocol for Testing Microbiological
Purifers"
Our Kold Ster-il ® offers a 0.20 Filter Bag capable of 99.999% reduction of
Cryptosporidium parvum cysts and 0.50µm Carbon Cartridge capable of greater
than 99.9% reduction tested according to the Standard & Protocol. Giardia &
Cryptosporidium parum cysts can cause serious illness or death in immune
suppressed individuals caused by disease or chemotherapy.